CT2M - Counter

Salient Features
  • Suitable for 3P, 4W LT Application.
  • Counter Type display.
  • Models available:
    a. Direct reading type.
    b. -/5A type.
  • Display:
    a. 6 digits for direct reading meter.
    b. 5+1 digits for -/5A meter.
  • No separate auxiliary supply is required.
  • Low power consumption, less than 1Watt/phase.
  • Potential free pulse output for external energy totalization.
  • Records KWh Energy Consumptions.
  • Available in Class Accuracy 1.0
Application
  • Industrial LT Panel.
  • Motor Control Centres, Distribution Contol & Relay Panels.
  • Air Conditioning and Refrigeration Panels.
  • Genset Panels.
  • Generation, Transmission and Distribution Panels.
  • Special OEM Application.
View Description Enquiry

CT2E - LCD

Salient Features
  • Suitable for 3P, 4W LT Application.
  • LCD type display.
  • No separate auxiliary supply is required.
  • Meter is suitable for 5A CT secondary.
  • CT primary selected from 5A to 6000A in steps of 5A.
  • CT Reverse Indication.
  • Potential free pulse output for external energy totalization.
  • Two push buttons on the front panel for programming.
  • Pulse output:
    a. 1pulse = 1KWh for direct reading meter.
    b. 1pulse = 100Wh for -/5A meter.
  • Low power consumption, less than 1Watt/Phase.
  • Records KWh Energy Consumptions.
  • Available in Class Accuracy 1.0
Application
  • Industrial LT Panel.
  • Motor Control Centres, Distribution Contol & Relay Panels.
  • Air Conditioning and Refrigeration Panels.
  • Genset Panels.
  • Generation, Transmission and Distribution Panels.
  • Special OEM Application.
View Description Enquiry

CT2EA - LCD With RS485

Salient Features
  • Suitable for 3P, 4W LT Application.
  • LCD type display.
  • Meter is suitable for 5A CT secondary.
  • CT primary selected from 5A to 6000A in steps of 5A.
  • CT Reverse Indication.
  • Potential free pulse output for external energy totalization.
  • Two push buttons on the front panel for programming.
  • Pulse output:
    a. 1pulse = 1KWh for direct reading meter.
    b. 1pulse = 100Wh for -/5A meter.
  • CT 2EA – with RS 485 MODBUS RTU communication.
  • Records KWh Energy Consumptions.
  • Available in Class Accuracy 1.0
Application
  • Industrial LT Panel.
  • Motor Control Centres, Distribution Contol & Relay Panels.
  • Air Conditioning and Refrigeration Panels.
  • Genset Panels.
  • Generation, Transmission and Distribution Panels.
  • Special OEM Application.
View Description Enquiry

CT2EMG

Salient Features
  • Measures kWh of 2 sources in one meter for three phase four wire LV electrical network.
  • Parameters measured:
    a. Active energy from mains supply (grid).
    b. Active energy from generator supply.
  • Separate Pulse Output for Mains/Generator energy.
  • LCD with backlit display.
  • Three push buttons on the front panel for programming.
  • Flashing Indication is provided on display to indicate the source in use.
  • Current Reversal Indication Provided on Display.
  • Available in Class Accuracy 1.0 & 0.5
  • Separate Models for AC & DC Sensing.
Application
  • Dual Energy registration mechanism records Mains Power as well as Genset Energy Consumption used for industrial application.
View Description Enquiry

CT2EMG Plus

Salient Features
  • Measures kWh of 2 sources in one meter for Three Phase Four Wire LV electrical Network.
  • Parameters measured:
    a. Active energy from mains supply (grid).
    b. Active energy from generator supply.
  • Separate Pulse Output for Mains/Generator energy.
  • LCD with backlit display.
  • Three push buttons on the front panel for programming.
  • Relay Outputs for V, I, kW, kVA, F, kW Demand, kVA Demand.
  • Last 6 months history Parameters for kWh, and MD through communication.
  • Last 10 event logging for Mains/Generator Switching.
  • Available in Class Accuracy 1.0 & 0.5
  • Separate Models for AC & DC Sensing
Application
  • Dual Energy registration mechanism records Mains Power as well as Genset Energy
    Consumption used for industrial application & Demand Controller.
View Description Enquiry